Services

Fuel Oil Delivery

Fuel Oil Delivery

Plumbing & Heating

Plumbing & Heating

Air Conditioning

Air Conditioning

Sewer & Drains

Sewer & Drains

Masonry

Well Water Systems

Carpentry & Painting

 

Employment with ASI

 

Our Service Plans

 

Plumbing & Heating Services

SAVE MONEY WITH MENU PRICING

For Service Work Only
We Charge By The Job Not By The Hour

No Emergency Charges or After Hours Rates

Specializing in Plumbing Installation and Repairs:
Additions, pex tubing repipes, kitchen faucets, garbage disposals, dishwashers, ice makers, tub & sink drains, lavatory faucets, toilets, tub & shower valves, water heaters - gas, oil, electric, sump pumps, sewer ejector pumps, washing machine valves, frozen pipes unthawed, and water meters.
* Freeze machine available due to lack of main emergency valve not working.

Specializing in Heating Iinstallation and Repairs:
American or European oil burners, American and European steam and hydronic boilers - oil and gas, warm air furnaces, duct work, outdoor remote sensors, towel warmers, hydro air units, high velocity AC systems, low profile baseboard, high output baseboard, radiant floor heating, boiler cleanings and tunings, no heat and hot water calls, indirect hot water storage tanks, oil tanks, ward flex gas piping, power venters, chimney liners, frozen pipes, anti-freeze heating systems and tankless coil repairs.

Specializing in Waste Oil Furnace Installation and Repairs
Servicing all makes and models

Freeze Machine Available For Emergency Shut-Off Valves That Are Not Operational

 

Water And Sewer Pipe Locator Available

 

42 Step Boiler, Hydronic or Steam & Warm Air Furnace & Oil Fired Hot Water Cleaning & Tunings

Procedures:

  1. Turn T-Stat up, Check operation of boiler
  2. Shut boiler off
  3. Shut oil tank valve off
  4. Check level in oil tank
  5. Change oil filter
  6. Close FOV at burner
  7. Open oil tank valve
  8. Remove Strainer
  9. Open burner FOV, allow all oil to flow until it is clean
  10. Put strainer back on
  11. Remove nozzle assembly
  12. Check boiler stamp plate for maximum allowed gallons
  13. Change appropriate nozzle
  14. Clean retention ring
  15. Look down blass tube for carbon deposits
  16. Put nozzle assembly back together with only retention nut
  17. Direct high pressure line into bucket
  18. Open up oil burner valve
  19. Open up 3/8 bleeder
  20. Run unit to bleed oil until safety lock out
  21. Close 3/8 bleeder
  22. Press reset
  23. Run oil through high prressure oil line until second safety lock out
  24. Test transformer with tester - not screwdriver
  25. Wipe cad cell eye clean
  26. Run unit and test ohms with ohm meter
  27. Shut switch off
  28. Remove oil from basement
  29. Remove panel for brushing down boiler
  30. Inspect chamber for cracks or deterioration
  31. Put panel back on boiler & seal if necessary
  32. Remove smoke pipe
  33. Inspect chimney opening
  34. Brush smoke pipe down
  35. Put smoke pipe back together
  36. Run system by starting and stopping several times
  37. Let system come up to temperature
  38. Final check for any oil leaks
  39. Wipe unit down with Simple Green
  40. Place sticker on unit
  41. Make out Pass/Fail check list
  42. Efficiency Testing